饥渴的熟妇张开腿呻吟视频_欧美老熟妇做受视频在线_亚洲综合爱爱_dy888午夜国产午夜精品_亚洲肥婆综合色区在线播放_蜜桃精品视频亚州激情_乱辈通轩系列小说_特节久久香蕉国产线看观看_色热热福利导航_欧美破苞系列二十三

600X electric control valve

Products > Hydraulic control valve > 600X electric control valve

600X electric control valve

Overview:
The hydraulic control valve is the hydraulic pressure control valve. The hydraulic control valve is composed of a main valve and its attached conduit, pilot valve, needle valve, ball valve, pressure reducing valve, slow closing check valve, flow control valve, pressure relief. Valves, hydraulic electric control valves, water pump control valves, etc. Filters should be installed before the hydraulic control valve, and the requirements for sewage discharge should be facilitated.
shared:

The hydraulic control valve is a hydraulic pressure control valve. The hydraulic control valve is composed of a main valve and its attached conduit, pilot valve, needle valve, ball valve, pressure reducing valve, slow closing check valve, flow control valve, pressure relief valve, Water power electric control valve, water pump control valve, etc. Filters should be installed before the hydraulic control valve, and the requirements for sewage discharge should be facilitated.

The 500X pressure relief / pressure valve king should be used in fire or other water supply systems to prevent system overpressure or maintain pressure on the fire water supply system. The impact of the water hammer can also be reduced after the fire pump is turned off. Also used in water hammer elimination devices for large water supply systems. And the inlet of the valve control system is equipped with a self-cleaning filter. The fluid characteristics make the suspended particles with larger specific gravity and larger diameter not enter the control system. Ensure that the system is unobstructed and the valve operates safely and reliably. The system operates smoothly, with high strength and long service life, and is suitable for pipelines up to 600 caliber. Valve structure features and uses.

The 500X pressure relief/pressure valve consists of a main valve, a pressure relief/pressure holding pilot needle valve, a ball valve, a microfilter and a pressure gauge to form a hydraulic control takeover system. It can be used as a pressure relief valve or as a pressure holding valve by hydraulic automatic operation. When used as a pressure relief valve, the water supply line pressure can be maintained below the set safety value; for the pressure holding valve, the upstream water pressure of the main valve can be maintained above the set value to maintain the upstream supply pressure of the main valve.

The 500X pressure relief/pressure valve utilizes hydraulic self-power control, requires no other equipment and energy, is easy to maintain, and is multi-purpose for one valve.

This series of 500X pressure relief / pressure valve products are widely used in high-rise buildings, living areas and other water supply pipe network systems and urban water supply projects.

500X pressure relief / pressure valve working principle

1. As a pressure relief valve: when the pressure relief/pressure holding pilot valve is adjusted to the pressure relief state, the water flows through the needle valve, the main valve control chamber, the ball valve A, the pressure relief/pressure holding pilot valve, and the ball valve B to the outlet. The main valve is open. When the inlet pressure exceeds the safe value set by the pressure relief/pressure holding pilot valve, the pressure relief pilot valve will automatically open, and part of the water is discharged through the ball valve C to relieve the pressure of the pipeline. The pressure relief valve automatically closes when the pressure returns to a safe value. When the pressure relief valve is used, each ball valve is normally open.

2. As the holding pressure valve: When the pressure relief/pressure holding pilot valve is adjusted to the holding pressure state, the pilot valve is closed as long as the main valve inlet water pressure is lower than the pilot valve setting value. The main control room is boosted and the main valve is closed. When the upstream supply pressure of the main valve exceeds the set pressure of the pilot valve, the holding pilot valve can be opened, the water in the control chamber is discharged to the outlet through the ball valve, and the main valve of the control chamber is opened, and the water supply is started, that is, the upstream water pressure is maintained. When used as a pressure holding valve, the ball valve C is normally closed or replaced with a wire plug.

 500X pressure relief / pressure valve main technical parameters

Nominal pressure (Mpa)

Shell test pressure (MPa)

Seal test pressure (MPa)

Applicable medium

Medium temperature (°C)

1.0

1.5

1.1

water

0-80

1.6

2.4

1.76

2.5

3.75

2.75

500X pressure relief / pressure valve main parts and materials

Part Name

Part material

Valve body bonnet

WCB

Seat valve disc

Copper alloy

Seal O-ring

Nitrile rubber

Valve stem

2Cr13

spring

50CrVA

Needle valve

Copper alloy

Ball valve

Copper alloy

Pressure relief / pressure holding pilot valve

Copper alloy

Micro filter

stainless steel


500X pressure relief valve connection size (PN 1.0-2.5MPa):

Nominal diameter DN

L

H

H1

A

B

50

250

335

90

170

170

65

280

345

98

180

180

80

310

355

110

190

190

100

350

365

120

200

200

125

400

445

145

215

215

150

450

460

155

230

230

200

550

505

190

255

255

250

650

550

250

295

295

300

800

710

290

325

325

350

900

725

330

380

380

400

1000

760

360

415

415

450

1000

810

445

435

435

500

1100

865

495

460

460

600

1100

935

550

520

520

700

1450

1000

605

570

570

800

1560

1100

730

620

620

900

1800

1205

800

670

670

1000

2000

1330

910

830

830